logo
Home > products > Disposable Spo2 Sensor >
Length 0.9M Disposable Spo2 Sensor Latex Free Adhesive Material

Length 0.9M Disposable Spo2 Sensor Latex Free Adhesive Material

0.9M Disposable Spo2 Sensor

Disposable Spo2 Sensor Latex Free

Adhesive Disposable Oxygen Sensor

Place of Origin:

China

Brand Name:

Med Accessories

Certification:

CE,ISO,SFDA

Model Number:

M400D series

Chat Now

Chat Now
Product Details
Category:
Disposable Spo2 Sensor
Length:
0.9M
Shelf Life:
2 Years
Material:
Adhesive
Instrument Classification:
Class II
Feature:
Latex-free
Payment & Shipping Terms
Minimum Order Quantity
1 Box
Packaging Details
24pcs/box
Delivery Time
About one week
Payment Terms
T/T
Product Description

 

Medical Manufacturer M Adult/Neonate Disposable SpO2 Sensor for M Radical-7

OEM Part Number References:

Manufacturer OEM Part #
M 4000 (RD SET Adt),4001 (RD SET Pdt),4002 (RD SET Inf),4003 (RD SET Neo Adult / Neonatal)

Compatibility monitor brands:

Manufacturer Model
Mindray > Datascope
Accutorr 3, Accutorr 7, ePM 10M, ePM 12M

 

Length 0.9M Disposable Spo2 Sensor Latex Free Adhesive Material 0

 

 

1. Product Name:

Medical Manufacturer M Adult/Neonate Disposable SpO2 Sensor for M Radical-7

 

2.Technical Parameters

Red 660nm±3 mm;
Infrared 905nm±5 mm/940nm

Accuracy range: SpO2 range (70~100%) --- ±3%;
Pulse rate declared accuracy range: 30~235bpm, ±2bpm
Usage Specifications:
- Operating temperature: 0-35℃
- Operating humidity: 15-85%RH
- Operating hyperbaric pressure: 88~108kPa
- transportation and Storage temperature: -30~+60℃
- transportation and Storage humidity: 15~80%RH
- transportation and Storage hyperbaric pressure: 85~105kPa

 

3. operation instructions

The above tables list models of Med Accessories disposable sensors for the following four categories of patients: adult (weight greater than 30 kg ),pediatric(10-50 kg weight ),infant (3-20 kg weight ),and neonatal/adult ( weight less than 3 kg or greater than 40kg ). Select the sensor model number that matches the brand of oximeter you are using.
Match the sensor model with your brand of oximeter. A mismatch may cause patient injury, inaccurate measurements or equipment damage. Check the sensor
every 2 hours and reposition to an alternate location every 24 hours. Avoid application of the sensors to edematous or fragile tissue Excessive patient motion,
excessive ambient light, electromagnetic interference, dysfunctional hemoglobin, low perfusion, intra vascular dyes, finger nail polish and long or artificial finger
nails may affect the sensor performance and the accuracy of the measurement Do not use the sensor if it is damaged. Use of a damaged sensor could cause patient
injury or equipment failure. Note: The materials used in the manufacture of the sensor contain no natural latex protein. The materials have undergone extensive
biocompatibility testing. Further information is available upon request.

 

 

 

Send your inquiry directly to us

Privacy Policy China Good Quality Spo2 Sensor Cable Supplier. Copyright © 2023-2025 spo2sensorcables.com . All Rights Reserved.